DOI: 10.36016/VM-2021-107-2



Veterinary Medicine: inter-departmental subject scientific collection. 2021. Issue 107. P. 15–18.


Download full text (PDF)


DIRECT FLUORESCENT ANTIBODY TEST IN LABORATORY DIAGNOSIS OF ANIMAL RABIES IN UKRAINE


Polupan I. M.

State Research Institute of Laboratory Diagnostics and Veterinary and Sanitary Expertise, Kyiv, Ukraine, e-mail: vetmedic@ukr.net

The aim of the study was to analyze the role of the direct fluorescent antibody (DFA) test in the system of laboratory diagnosis of animal rabies in Ukraine. For the analysis, materials of official veterinary reporting were used according to Form No. 2-VET “Report on the work of the state laboratories of veterinary medicine” regarding the results of laboratory studies of pathological material suspicious of rabies, the State Research Institute of Laboratory Diagnostics and Veterinary and Sanitary Expertise (SRILDVSE) and virology departments of the State Regional Laboratories of the State Food and Consumer Service of Ukraine, and analytical materials: Report “On the assessment of the risk of spread of rabies among domestic and farm animals under the current animal rabies control system in Ukraine” and the Report “On the assessment of the risk of spread of rabies among wild animals in Ukraine”. It has been determined that, over the past 15 years (2006–2020), 194,079 tests of the pathological material were carried out in state laboratories. The direct fluorescent antibody test is the main technique for the diagnosis of animal rabies in Ukraine, when used in 94.5% of cases, the final diagnosis of rabies is made. We have used standardization of approaches, including the use of the reference rabies virus CVS-11 (ATCC VR 959), to the organization and conducting of interlaboratory rounds of professional testing VET-TEST to identify of rabies virus antigen within the requirements ISO 17043:2017 “Conformity assessment. General requirements for testing professional level”. DFA test is the main reaction for the diagnosis of rabies in animals in Ukraine. Standardized approaches were introduced and interlaboratory rounds of professional testing BET-TEST have been organized in 2020 for the detection of rabies virus antigen in accordance with the quality standard ISO 17043:2017. The necessity of introducing new methods of laboratory diagnostics of rabies, such as viral isolations in tissue culture and polymerase chain reaction, has been established

Keywords: monitoring, express test, ATCC VR 959


References

World Health Organization. WHO expert consultation on rabies: Third report. Geneva: WHO, 2018. 195 pp. (WHO Technical Report Series, Vol. 1012). ISBN: 9789241210218. URL: https://apps.who.int/iris/handle/10665/272364.

Недосєков В. В., Гришок Л. П., Полупан І. М., Іванов М. Ю. Оздоровлення території України від сказу — невідкладні завдання науки і практики. Ветеринарна медицина України. 2009. № 2. С. 12–13.

Mazur N., Nedosekov V., Polupan І. The role of the fat in laboratory diagnosis of rabies. Veterinary Biotechnology : bulletin. Kyiv, 2015. Iss. 26. С. 232–236. URL: http://nbuv.gov.ua/UJRN/vbtb_2015_26_33.

Polupan I. M., Nedosekov V. V., Stepanova T. V., Rudoi O. V., Parshikova A. V., Drozdova E. I. Molecular characteristics isolates of rabies virus isolated from humans in Ukraine. IOP Conference Series: Earth and Environmental Science. 2021. Vol. 677. Р. 042025. DOI: https://doi.org/10.1088/1755-1315/677/4/042025.

World Organisation for Animal Health (OIE). Chapter 3.1.17. Rabies (infection with rabies virus and other lyssaviruses) [version adopted in May 2018]. In: Manual of Diagnostic Tests and Vaccines for Terrestrial Animals (Mammals, Birds and Bees). 8th ed. Paris : OIE, 2018. P. 578–612. URL: https://www.oie.int/fileadmin/Home/eng/Health_standards/tahm/3.01.17_RABIES.pdf.

Hanlon C. A., Smith J. S., Anderson G. R. (1999). Recommendations of a national working group on prevention and control of rabies in the United States. Article II: Laboratory diagnosis of rabies. The National Working Group on Rabies Prevention and Control. Journal of the American Veterinary Medical Association. 1999. Vol. 215, iss. 10. P. 1444–1446. PMID: https://pubmed.ncbi.nlm.nih.gov/10579039.

Tepsumethanon V., Lumlertdacha B., Mitmoonpitak C., Fagen R., Wilde H. Fluorescent antibody test for rabies: prospective study of 8,987 brains. Clinical Infectious Diseases. 1997. Vol. 25, iss. 6. P. 1459–1461. DOI: https://doi.org/10.1086/516151.

Robardet E., Picard-Meyer E., Andrieu S., Servat A., Cliquet F. International interlaboratory trials on rabies diagnosis: An overview of results and variation in reference diagnosis techniques (fluorescent antibody test, rabies tissue culture infection test, mouse inoculation test) and molecular biology techniques. Journal of Virological Methods. 2011. Vol. 177, iss. 1. P. 15–25. DOI: https://doi.org/10.1016/j.jviromet.2011.06.004.

Державна служба України з питань безпечності харчових продуктів та захисту споживачів. Звіти про проведені оцінки ризиків. URL: https://dpss.gov.ua/diyalnist/ocinka-riziku/zviti.

Полупан І. М., ред. Планування, організація та проведення пероральної імунізації м’ясоїдних тварин проти сказу : метод. реком. Київ : ПП "Тім-Сервіс К", 2019. 30 с.

Polupan I., Bezymennyi M., Gibaliuk Y., Drozhzhe Z., Rudoi O., Ukhovskyi V., Nedosekov V., De Nardi M. An analysis of rabies incidence and its geographic spread in the buffer area among orally vaccinated wildlife in Ukraine from 2012 to 2016. Frontiers in Veterinary Science. 2019. Vol. 6. P. 290. DOI: https://doi.org/10.3389/fvets.2019.00290.

Полупан І. М., Дрожже Ж. М., Гібалюк Ю. О., Шарай Я. М. Удосконалення системи антирабічних заходів в Україні. Вісник Дніпропетровського державного аграрно-економічного університету. 2018. № 1–2. С. 149–152. URL: http://nbuv.gov.ua/UJRN/vddau_2018_1-2_28.

image description

2010-2024 © ННЦ ІЕКВМ Всі права захищено.

image description